Standard item TYP M, for heavy duty applications glycerine filled TYP RMG
Temperature range -40° C to 100° C, for glycerine filled Type RMG -20° C to 70° C, Housing AISI 304, Measuring piece in medium: AISI 316Ti, Sight glass: safety glass. Accuracy: Class 1.0 for NG 100 and 160, Class 1,6 for NG 40 and 63. This represents a display value of better than ±1.0 % or 1.6 % for a scale value at 20° C. Design features: Bourdon tube, threaded spring carrier, indicator unit, scale and indicators are forming a complete unit that can be interchanged fully functional. The body and the ring with the glass are basically only a protection against external influences. The scale (with black print), the display range, the scale divisions and the numbering are designed according to DIN. Gauges with glycerine filling, Type RMG: are used for heavy duty applications such as vibration, strong pressure fluctuations or condensation.