Also available with Reed switch (can be installed on a track, electrical contact hermetically separated from the medium).
Order Code: for gauge: MR-SDA2-110G114, for control with Reed switch: MR-SDAR2-110G114. Max. operating temperature 100° C, Housing AISI 304, Suspended gauge AISI 304, on request PP, Material of the slit nozzle 1.3955, Seal Viton®, on request NBR. Accuracy ± 4%, Scaling: For water, for fluids with other viscosities on request.
Operation: The upward streaming medium pushes the float, which is situated in the cylindrical guide pipe, straight up. The more medium is floating the higher the float is pushed. A permanent magnet situated in the float is moving a flow indicator that is hermetically isolated on the outside of the gauge. With this it guarantees an exact indication also with high pressures.
With Reed switch: A permanent magnet situated in the float activates the Reed switch as soon as the magnetic field reaches its contact. The Reed switch can be individually adjusted on a bar on the outside and therefore be used as a flow controller. A high grade of operational reliability is granted by using magnetism and gravity. Wearing parts such as springs or diaphragms are not necessary.
Attention: Not suitable for mediums that contain magnetisable parts (except if you use magnetic filters).