![u2-Lok Twin ferrule fittings / Valves and fittings / Check Valve u2-Lok Twin ferrule fittings / Valves and fittings / Check Valve](https://www.schwer.com/dynimg/0JPCA-0vXGLwqwFMuMZ5udcUcLo=/0x0:0x0/full-fit-in/260x260/filters:no-upscale():cachevalid(2015-06-12T09:23:34)/Documents/Produktbilder/PB_u2/u2-CV.jpg)
![u2-Lok Twin ferrule fittings / Valves and fittings / Check Valve (6000 PSI) u2-Lok Twin ferrule fittings / Valves and fittings / Check Valve (6000 PSI)](https://www.schwer.com/dynimg/v8IUJmcBqPzw4i9hO-bxYl9dbg8=/0x0:0x0/full-fit-in/260x260/filters:no-upscale():cachevalid(2020-04-20T08:39:58)/Documents/Produktbilder/PB_u2/u2-CV6.jpg)
![u2-Lok Twin ferrule fittings / Valves and fittings / Check Valve u2-Lok Twin ferrule fittings / Valves and fittings / Check Valve](https://www.schwer.com/dynimg/NlfwJUBlFySrp-Hdn3Tvfidsw7k=/0x0:0x0/full-fit-in/260x260/filters:no-upscale():cachevalid(2015-06-12T09:23:31)/Documents/Produktbilder/PB_u2/u2-CVF.jpg)
![u2-Lok Twin ferrule fittings / Valves and fittings / Check Valve (G) u2-Lok Twin ferrule fittings / Valves and fittings / Check Valve (G)](https://www.schwer.com/dynimg/NlfwJUBlFySrp-Hdn3Tvfidsw7k=/0x0:0x0/full-fit-in/260x260/filters:no-upscale():cachevalid(2015-06-12T09:23:31)/Documents/Produktbilder/PB_u2/u2-CVF.jpg)
![u2-Lok Twin ferrule fittings / Valves and fittings / Check Valve (NPT) u2-Lok Twin ferrule fittings / Valves and fittings / Check Valve (NPT)](https://www.schwer.com/dynimg/UPtxi8SvfulNioyPBCFu4QA7Z8Y=/0x0:0x0/full-fit-in/260x260/filters:no-upscale():cachevalid(2020-03-26T08:12:38)/Documents/Produktbilder/PB_u2/u2-CVM-N.jpg)
![u2-Lok Twin ferrule fittings / Valves and fittings / Check Valve (G) with captive seal u2-Lok Twin ferrule fittings / Valves and fittings / Check Valve (G) with captive seal](https://www.schwer.com/dynimg/djISrJMNbgzT1RlLb-S7RORGlmI=/0x0:0x0/full-fit-in/260x260/filters:no-upscale():cachevalid(2020-03-26T08:45:16)/Documents/Produktbilder/PB_u2/u2-CVM-G-ES.jpg)
![u2-Lok Twin ferrule fittings / Valves and fittings / Check Valve (G) with metal sealing edge u2-Lok Twin ferrule fittings / Valves and fittings / Check Valve (G) with metal sealing edge](https://www.schwer.com/dynimg/ONhlfalFZx2YJjiQML-unyU8rKI=/0x0:0x0/full-fit-in/260x260/filters:no-upscale():cachevalid(2020-03-26T08:12:35)/Documents/Produktbilder/PB_u2/u2-CVM-G-CS.jpg)
![u2-Lok Twin ferrule fittings / Valves and fittings / Needle Valve (5000 PSI) u2-Lok Twin ferrule fittings / Valves and fittings / Needle Valve (5000 PSI)](https://www.schwer.com/dynimg/LjrQro-sb2wsKJWm7bfvDpoMfJk=/0x0:0x0/full-fit-in/260x260/filters:no-upscale():cachevalid(2015-05-19T10:22:58)/Documents/Produktbilder/PB_u2/u2-NV.jpg)
![u2-Lok Twin ferrule fittings / Valves and fittings / Needle Angle Valve (5000 PSI) u2-Lok Twin ferrule fittings / Valves and fittings / Needle Angle Valve (5000 PSI)](https://www.schwer.com/dynimg/jv7pGDijAAFYpREU5aKS71QNtCk=/0x0:0x0/full-fit-in/260x260/filters:no-upscale():cachevalid(2015-05-19T10:22:43)/Documents/Produktbilder/PB_u2/u2-NAV.jpg)
![u2-Lok Twin ferrule fittings / Valves and fittings / Proportional Relief Valve u2-Lok Twin ferrule fittings / Valves and fittings / Proportional Relief Valve](https://www.schwer.com/dynimg/TsHTxdZTb01S8y1RaCiq3xBRl88=/0x0:0x0/full-fit-in/260x260/filters:no-upscale():cachevalid(2022-05-25T14:25:03)/Documents/Produktbilder/PB_u2/u2-PRV-p6.jpg)
![u2-Lok Twin ferrule fittings / Valves and fittings / Proportional Relief Valve (NPT) Proportional Relief Valve (NPT)](https://www.schwer.com/dynimg/mF-2py7frE-1yCbzGCThTP8FwY8=/0x0:0x0/full-fit-in/260x260/filters:no-upscale():cachevalid(2022-05-25T14:25:00)/Documents/Produktbilder/PB_u2/u2-PRV-N-p6.jpg)
![u2-Lok Twin ferrule fittings / Valves and fittings / Spring Set u2-Lok Twin ferrule fittings / Valves and fittings / Spring Set](https://www.schwer.com/dynimg/5d-PCz1Yij_bkmKldc4LjqNeVgQ=/0x0:0x0/full-fit-in/260x260/filters:no-upscale():cachevalid(2022-05-25T14:25:05)/Documents/Produktbilder/PB_u2/u2-PSS1.jpg)
![u2-Lok Twin ferrule fittings / Valves and fittings / 2-Way Low Pressure Ball Valve (up to 1.000 PSI) u2-Lok Twin ferrule fittings / Valves and fittings / 2-Way Low Pressure Ball Valve (up to 1.000 PSI)](https://www.schwer.com/dynimg/tLHNOmFk5D92d7BwWa2P5NdPE2Q=/0x0:0x0/full-fit-in/260x260/filters:no-upscale():cachevalid(2014-09-16T08:50:09)/Documents/Produktbilder/PB_u2/u2-BV1mHLD-4iP.jpg)
![u2-Lok Twin ferrule fittings / Valves and fittings / 2-Way Medium Pressure Ball Valve (up to 2.000 PSI) u2-Lok Twin ferrule fittings / Valves and fittings / 2-Way Medium Pressure Ball Valve (up to 2.000 PSI)](https://www.schwer.com/dynimg/mJjJ1IUjyO9psnzcJSzQ3UR7IS0=/0x0:0x0/full-fit-in/260x260/filters:no-upscale():cachevalid(2020-06-25T10:13:03)/Documents/Produktbilder/PB_u2/u2-BV2HLD-4LiP.jpg)
![u2-Lok Twin ferrule fittings / Valves and fittings / 2-Way High Pressure Ball Valve (3000 psi) u2-Lok Twin ferrule fittings / Valves and fittings / 2-Way High Pressure Ball Valve (3000 psi)](https://www.schwer.com/dynimg/x63_CCnynL_BYA_SYKpnGN8y0TA=/0x0:0x0/full-fit-in/260x260/filters:no-upscale():cachevalid(2020-05-25T08:55:33)/Documents/Produktbilder/PB_u2/u2-BV3000psi.jpg)
![u2-Lok Twin ferrule fittings / Valves and fittings / 2-Way High Pressure Ball Valve (6.000 PSI) u2-Lok Twin ferrule fittings / Valves and fittings / 2-Way High Pressure Ball Valve (6.000 PSI)](https://www.schwer.com/dynimg/eANNXHegOKLMtq12BAJIQYnX0m8=/0x0:0x0/full-fit-in/260x260/filters:no-upscale():cachevalid(2020-12-01T10:34:18)/Documents/Produktbilder/PB_u2/u2-BV-6000psi.jpg)
![u2-Lok Twin ferrule fittings / Valves and fittings / 2-Way High Pressure Ball Valve (6.000 PSI) 2-Way High Pressure Ball Valve (6.000 PSI)](https://www.schwer.com/dynimg/zwL66KhYfJoIp7-r9VzAcXgC7o0=/0x0:0x0/full-fit-in/260x260/filters:no-upscale():cachevalid(2020-12-01T10:34:20)/Documents/Produktbilder/PB_u2/u2-BVF-G6000.jpg)
![u2-Lok Twin ferrule fittings / Valves and fittings / 2-Way High Pressure Ball Valve (6.000 PSI) 2-Way High Pressure Ball Valve (6.000 PSI)](https://www.schwer.com/dynimg/6zywdXkORjA2OrctMZmNqJxTKOQ=/0x0:0x0/full-fit-in/260x260/filters:no-upscale():cachevalid(2020-12-01T10:34:37)/Documents/Produktbilder/PB_u2/u2-BVF-N6000.jpg)
![u2-Lok Twin ferrule fittings / Valves and fittings / Adjustable 2-Way Low Pressure Ball Valve u2-Lok Twin ferrule fittings / Valves and fittings / Adjustable 2-Way Low Pressure Ball Valve](https://www.schwer.com/dynimg/l5NcK1RJhE53IjKpFa9_nq9qTTA=/0x0:0x0/full-fit-in/260x260/filters:no-upscale():cachevalid(2022-10-06T10:28:12)/Documents/Produktbilder/PB_u2/u2-BV2-AG-PV.jpg)
![u2-Lok Twin ferrule fittings / Valves and fittings / Check Valve (6000 psi) Check Valve (6000 psi)](https://www.schwer.com/dynimg/u296SBbFw0_28vjB4PjF3EFCPGE=/0x0:0x0/full-fit-in/260x260/filters:no-upscale():cachevalid(2023-03-10T08:00:44)/Documents/Produktbilder/PB_u2/u2-LCV.jpg)
Functionally matched tolerances and consistent surface finish with clamping wedge ring fittings ensure leak-free pipe connections in both the high pressure and in vacuum. Vibration and pressure surges are largely absorbed by the design of the clamping wedge ring structure without any leakage are to be feared.
Additional features like easy installation, great variety in metric and imperial range, quality surface roughness due to modern manufacturing technology secure the clamping wedge ring -fitting to a wide range of applications throughout the industry, as well as in the laboratory and in metrology.
Using high grade stainless steels a long "life" in an aggressive environment is ensured.
Other material grades 1.4571, Hastelloy, Titanium and other highly material qualities are available.
Even under heavy vibration the couplings ensure adequate security at high pressures or vacuum. This is achieved by 4-efficient construction details:
1. The clamping ring with its spring-like formation dampens vibrations from the pipe network. Furthermore, it prevents transmission of the tightening torque of the nut on the wedge ring.
2. The wedge ring seals the pressing surfaces between fitting and pipe. Due to the taper in the hole of the tapered ring it’s pressed onto the pipe, so that a constriction arises, whereby the tube is clamped pressure tight.
3. A special surface treatment of the fine thread of the union nut is used to prevent seizure. This allows the multiple use of the same tube easily.
4. A longer tube guide ensures an accurate tight fit, manufacturing tolerances ensure reliable centering of the pipe.
Deutschland:
UPS Standard: 3-4 Tage
UPS Express Saver: 1-2 Tage
Europa: 4-5 Tage / Europe: 4-5 days
Please log in with your login so you can see the price information.
As a guest, you can add items to the shopping cart and inquire.
The product has been added successfully.
The length of a hose assembly is always measured between the sealing heads or, in the case of angled fittings, between the center points of the fitting.
Minimum hose length: 250 mm
The orientation is as follows: